TXV Brazing Tips And Liquid Line Filter Driers
When brazing a TXV (thermostatic expansion valve) it must be done correctly. We also discuss liquid line filter driers briefly with Jamie Kitchen from Danfoss. The TXV brazing tips included in this video include the following:
1. Getting the heat on and off quick
2. Pointing the torch away from the valve
3. Protecting the valve from heat with heat absorbing putty (WetRag Putty)
4. Ensuring there is good silfos penetration and a potential shoulder
5. Nitrogen brazing
In this video we are using the Ambro Controls Oxyset with Precision Torch Tip, which allows technicians to carry a light weight tool and offers easier access into smaller cabinets due to its size.
Check out Jobber getjobber.com/hvacknowitall
Save 8% on your purchase at www.trutechtools.com/ with promo code knowitall
Check out the HVAC Know It All app app.hvacknowitall.com
www.hvacknowitall.com/pages/about
Visit HVAC Know It All on social media
Facebook
hvacknowitall/
Instagram
hvacknowitall1
Переглядів: 3 133

Відео

Evaporator Delta T vs Evaporator Temperature Difference
Переглядів 2 тис.Місяць тому
Evaporator Delta T and Evaporator Temperature Difference are different. Some HVAC technicians, helpers, and apprentices can get them confused. Both readings are very important in HVAC troubleshooting and require knowledge of how to attain them. Evaporator Delta T is the measurement of two points of the same medium, like air or water. Evaporator Temperature Difference is the measurement of two p...
Discover The Ultimate Media Air Filter To Stop Particulate Bypass And Eliminate Pressure Drop!
Переглядів 7435 місяців тому
An air filter and filter cabinet combo that has the potential for particulate bypass will create issues within an HVAC system. For instance, any dirt/debris that is not captured can get caught on the secondary heat exchanger of a high efficiency furnace and/or evaporator coil of an air conditioning system. This can plug the surface and also cause condensate management issues. Choosing a deep pl...
Unlocking The Secrets To Dominating Commercial HVAC As A Residential Tech
Переглядів 1,5 тис.5 місяців тому
Making the move from residential HVAC technician to commercial HVAC technician is big step in one's career. There are differences that must be discussed and challenges that must be overcome. There is more walking, climbing and lifting in commercia HVAC. There is also bigger equipment with more complex controls. The capacity to learn and expand your knowledge is definitely a bonus. In most cases...
How Does Flame Rectification Work On A Heating Season
Переглядів 1,8 тис.5 місяців тому
Flame rectification is the process of changing an AC signal to a DC signal. During flame rectification, the ignition control will send an AC signal in the range of 90v to 120v, from the flame sense terminal. That signal is sent down the flame sensor wire and through the flame sensor, it is rectified using the flame as part of the circuit and allowing the signal to come in contact with ground. A...
Carrier Rooftop Gas Valve Replacement After Going Off On High Limit
Переглядів 2,5 тис.8 місяців тому
Last winter this Carrier rooftop unit was going off on high limit. There was a problem with the gas valve in high fire and there was also a problem with the bypass damper on this zoned system. The gas valve pressure would creep up slowly over time from 3.5" wc to almost 4" wc within a few minutes of operation. For this reason, it had to left in low fire. The bypass damper was stuck in a closed ...
How To Use A Hub Puller Using The Supco Hub Blaster
Переглядів 3,1 тис.9 місяців тому
Sometimes we run into seized fan blades or fan wheels. Utilizing a fan/wheel or hub puller can help in these situations. In this video we are using the Supco Hub Blaster to demonstrate how to use a hub puller correctly. Here are the steps in order: - Lubricate the hub puller threads - Clean the motor shaft and add lubrication to the shaft - Fasten the hub puller to the fan hub - Break the seize...
3 HVAC and Refrigeration Tools That Changed The Game
Переглядів 4,4 тис.9 місяців тому
Three tools, in HVAC and refrigeration, that over the past year have had tremendous value for me and my company. Testo Smart Probes Testo smart probes are quick and easy to set up. Paired with the Testo Smart app, you receive readings quickly on one screen. Readings like pressures, temperatures, superheat and subcooling are vital to HVAC and refrigeration system operation. Check out our video c...
High Rise Geothermal The And Future Of Hydronics Pumping Technology
Переглядів 1,4 тис.Рік тому
We visit a very cool high rise geothermal system (drilling done by Geosource) that was installed recently in place of resistive heating (base board heaters). Each suite in the building has a stand alone heat pump that is individually controlled and fed by duty-standby pumps. The geothermal loop also has a set of duty-stanby pumps. The thermal exchange between geo and building is done through a ...
Ambro Controls OXYSET Demonstration - HVAC/R Brazing With Torches
Переглядів 15 тис.Рік тому
Ambro Controls OXYSET is a light weight torch kit designed for brazing jobs within the HVAC/R industry. The set uses mapp gas, oxygen and the torch temperature reaches brazing temperatures at approximately 5500 degrees Fahrenheit. The video explains the OXYSET torches, what comes in the kit, how much it weighs, how long the tanks last and how to set the oxygen and mapp gas cylinders properly. L...
Dual Fuel Heat Pump Install Tips - How To Install A Heat Pump
Переглядів 25 тис.Рік тому
We walk through a cold weather, dual fuel inverter heat pump install and install tips. A dual fuel heat pump system relies on the heat pump as the primary heating source with the furnace being its back up. Every dual fuel heat pump job should start with an on site assessment and load calculation. It's also very important to use the proper thermostat, that's capable of controlling dual fuel syst...
How To Install A Drain Pan Heater On A Cold Weather Heat Pump
Переглядів 6 тис.Рік тому
Heat pumps accumulate ice/frost in the heating cycle on the outdoor unit. During the defrost cycle, the ice/frost will melt and water will drain out the bottom. In cold weather applications, you may need a pan heater so the water does not re-freeze into ice. Ice accumulation at the bottom of the outdoor pan can cause issues with fan obstruction and potentially cause coil damage if the ice is al...
Gas Company Locked Out The Meter - Said There Was Gas Leak
Переглядів 18 тис.Рік тому
Gas Company Locked Out The Meter - Said There Was Gas Leak
How To Check Furnace Actual Capacity vs. Rated Capacity
Переглядів 6 тис.Рік тому
How To Check Furnace Actual Capacity vs. Rated Capacity
Finding An Electrical Short Within An HVAC RTU - Fuses Keep Blowing
Переглядів 22 тис.Рік тому
Finding An Electrical Short Within An HVAC RTU - Fuses Keep Blowing
Flame Roll Out And The Reason Why On A Carrier Rooftop
Переглядів 15 тис.Рік тому
Flame Roll Out And The Reason Why On A Carrier Rooftop
How To Set Up A Universal Ignition Control For HVAC - Emerson White-Rodgers All-Spark
Переглядів 2,5 тис.Рік тому
How To Set Up A Universal Ignition Control For HVAC - Emerson White-Rodgers All-Spark
Emerson White-Rodgers Premium Flame Sensor Installation - Universal Heating Part
Переглядів 3,4 тис.Рік тому
Emerson White-Rodgers Premium Flame Sensor Installation - Universal Heating Part
How To Troubleshoot A Flame Sensor With A Megohmmeter To Check The Ceramic Insulator
Переглядів 33 тис.Рік тому
How To Troubleshoot A Flame Sensor With A Megohmmeter To Check The Ceramic Insulator
Evaporator Coil Sanitization With APCO-X - How To Install A UV Light
Переглядів 4,8 тис.Рік тому
Evaporator Coil Sanitization With APCO-X - How To Install A UV Light
APCO-X Installation - UVC For Indoor Air Quality
Переглядів 3,8 тис.Рік тому
APCO-X Installation - UVC For Indoor Air Quality
How Check Total External Static Pressure On An Air Handler Or Furnace
Переглядів 34 тис.Рік тому
How Check Total External Static Pressure On An Air Handler Or Furnace
When Should A Technician Start Their Own HVAC/R Company - Business Ownership
Переглядів 31 тис.Рік тому
When Should A Technician Start Their Own HVAC/R Company - Business Ownership
RSH - VRM60A Voltage Monitor and RSH - 50 Surge Protector Install On A Condensing Unit
Переглядів 2,7 тис.Рік тому
RSH - VRM60A Voltage Monitor and RSH - 50 Surge Protector Install On A Condensing Unit
Brazing Alternatives For The HVAC/R Tech - Requires No Nitrogen
Переглядів 25 тис.Рік тому
Brazing Alternatives For The HVAC/R Tech - Requires No Nitrogen
Using A Thread Sealant (Nylog) To Seal Refrigerant Leaks
Переглядів 9 тис.Рік тому
Using A Thread Sealant (Nylog) To Seal Refrigerant Leaks
AC Service Call - Diagnosis And Refrigerant Leak Check
Переглядів 6 тис.Рік тому
AC Service Call - Diagnosis And Refrigerant Leak Check
Emerson Multi-Volt SureSwitch Walk Through and Installation - Contactor Replacement
Переглядів 3,8 тис.2 роки тому
Emerson Multi-Volt SureSwitch Walk Through and Installation - Contactor Replacement
Auto Charging By Subcooling w/ The Testo 560i Scale and Smart Valve
Переглядів 28 тис.2 роки тому
Auto Charging By Subcooling w/ The Testo 560i Scale and Smart Valve
SUPCO TradeFox Refrigerant Line Cleaning Kit - For Line Set Flushing
Переглядів 9 тис.2 роки тому
SUPCO TradeFox Refrigerant Line Cleaning Kit - For Line Set Flushing

КОМЕНТАРІ

  • @jaybusa7690
    @jaybusa7690 День тому

    Make this is EXCELLENT EXPLANATION!!! Wgreat video

  • @dubking-dm4wu
    @dubking-dm4wu 3 дні тому

    can i use this for lifting things on roofs just extend the rope

  • @liudxdx
    @liudxdx 6 днів тому

    Man you are a hero. I have watched over 20 videos on how heat pump works, I was so confused, like fucking water actually mix with refrigerant? Like wtf, nobody mentioned or explained the coaxial coil and how it works. Thanks god I found your video

  • @marvinmurray5520
    @marvinmurray5520 6 днів тому

    Thanks bro!

  • @hvguy
    @hvguy 8 днів тому

    Just what I needed! I was wondering why no freon was going in.... Turns out I have no idea what I'm doing. But now I kinda do!

  • @Dicktoben
    @Dicktoben 9 днів тому

    I stared my hvac business in Canada 12 years ago. I’ve always just wanted a balanced work life. I knew very little about business and hard to learn thru a lot of bumps. I was tired of working for somebody, counting on the weather to keep us busy. It’s so hard to get ahead in business, especially with the crazy economy. Here it’s hard to sell a 3 ton a/c system for 5000$. I see guys in the states that wouldn’t touch it for less than 10-15k. Business stresses me out. I’m tired of the rollercoaster and catch up game that always seems to be going on. Sometimes I wish I never got into this. There is a few perks for sure , but sometimes I just wish I stayed working for the man

  • @louievil713
    @louievil713 9 днів тому

    Nice thank you I'm getting 15.7 across all three leg start run and common. It was a little hot but all three legs are Reading the same so it is not grounded or in thermal lockout. But when the 24 volts are engaged the compressor stays at 290 on the low side and high side it is not adjusting in any way.

  • @Mudo94
    @Mudo94 10 днів тому

    Any review on the pocket version I think it’s the pocket 2

  • @mclmm6773
    @mclmm6773 13 днів тому

    Usually one of the worst issues these units have that is always not addressed at the factory is bad soft foot from those formed bases. I routinely see 0.020-0.050” soft foot.

  • @boywhohadatiger
    @boywhohadatiger 14 днів тому

    Found one like that on a carrier today tripping the breaker

  • @BernWag
    @BernWag 14 днів тому

    can you cut steel with that rig? Also, when brazing, do you have the option of using just MAPP or do you have to use O2 all the time?

  • @l.crossjr
    @l.crossjr 14 днів тому

    Geat video. I know you did not flow nitro for demonstration purposes, what is the best way to remove those flakes from that txv afterwards?

  • @JorgeMontes-ji2sd
    @JorgeMontes-ji2sd 15 днів тому

    Boring mtfkr

  • @jgarcia8067
    @jgarcia8067 16 днів тому

    How much was the set, an estimate since it was last year. And how much is each tank? 🤔✌🏾 I’ll plan ahead, thanks in advance.

  • @Ray-gf4vf
    @Ray-gf4vf 18 днів тому

    the whole static pressure is a shit fools gimic to make more money

  • @ja2553
    @ja2553 19 днів тому

    Golf clubs? Lame.

    • @HVACKnowItAll
      @HVACKnowItAll 18 днів тому

      The fact you took tike to leave a negative comment is lame lol. Here's a hug pal.

  • @Ray-wr2wr
    @Ray-wr2wr 19 днів тому

    Is it Boost spp6 would be efficient for 45+5 mdf capacitor? Thanks!

  • @sarahgibon5610
    @sarahgibon5610 19 днів тому

    .

  • @odl1307
    @odl1307 20 днів тому

    Hey is it possible to use the super evac manifold on a Mitsubishi heat pump for example the MXZ models when pulling vacuum, on the port inside the heat pump? Basically I was wondering if it’s possible to connect 2 hoses there to pull a vacuum faster. @hvacknowitall

  • @ShahidKhan-ws8rc
    @ShahidKhan-ws8rc 22 дні тому

    You have comprehensively covered the whole topic in such a short description n video. It's an incredible brief technical guide

  • @chrissipple1018
    @chrissipple1018 22 дні тому

    Always ask if the nitrogen cylinder has been used for clean nitrogen only. Sometimes the cylinder was used for some other gas and it just gets repainted. If it has had some other gas in it you now have dirty nitrogen and you can get high levels of copper oxide inside even though it's clean gas. If possible get only medical grade nitrogen, the sales person will probably give you a strange look but tell them that is what you want. And even with clean and pure nitrogen you will get some copper oxide build up.

  • @angrynas9668
    @angrynas9668 22 дні тому

    Cheking superheat near desire temperature

  • @l.crossjr
    @l.crossjr 22 дні тому

    Very good

  • @rv10flyer84
    @rv10flyer84 22 дні тому

    Heat the joint first. If your gap is snug, heat will transfer quickly to pipe. If not snug, use a lever type swaging tool.

  • @josecruz3237
    @josecruz3237 23 дні тому

    The 40 F minus 75 F in my opinion . The 40 F . is just the temperature at what the refrigerant begins to boil with out gaining any heat just as soon passed through the metering device. The more standard temperature measurements is Delta T . Temperature of the air coming in the evaporator and temperature coming out of the evaporator. The other temperature that is importance is S.H that is the gain of heat in the refrigerant after it saturated or is changing state from liquid to vapor. But this is a different way to see the temperature difference Thanks

    • @HVACKnowItAll
      @HVACKnowItAll 23 дні тому

      TD is used in coil design and is very important.

  • @steveashcraft718
    @steveashcraft718 24 дні тому

    My Heil furnace is eating blower wheels. It's getting it's second wheel this week. They're only lasting maybe 4 years.

    • @HVACKnowItAll
      @HVACKnowItAll 22 дні тому

      Buy a better, more expensive wheel! Or have your airflow and staic pressure checked.

    • @steveashcraft718
      @steveashcraft718 22 дні тому

      @@HVACKnowItAll , My HVAC man is using OEM wheels. I'm not the only one having this problem.

  • @espinozajc64
    @espinozajc64 24 дні тому

    Excellent 😊

  • @scoobtoober2975
    @scoobtoober2975 24 дні тому

    What's an acceptable pressure check drop in PSI over 10 or 20 min. 1 or 2 psi. Is there a few psi range that temperature of the gas can fluctuate. Depending on the bottle temp vs system temp. I'm praying you tell me the good news. I let the gas into the system. It held 250 micron vac for 15 min no problem. I had to fiddle with the setup a bit. Most of these inverter systems have 3/8 ports and i didn't have 3/8 to 3/8 hoses or enough adapters. And cheap core removal tools. One of them leaked. one didn't. And some don't grab the core. Check that too

  • @scoobtoober2975
    @scoobtoober2975 24 дні тому

    Surf bro channel highlighted the white textured insulation falls apart and corrodes line sets. I confirm that with a neighbors unit, a few years old. It looks like someone hit it with a torch and it's just gone in many spots. UV eats is. And it corroding the set quite bad. Those guys love the k-flex. I'd consider buying that stuff for sure. I premade set has jumbo neoprene style and it tears, but not as bad as i thought. But it definitely doesn't glide at all. And will help get it stuck in a whole and bunch up.

  • @scoobtoober2975
    @scoobtoober2975 24 дні тому

    3/4 by hand kinks fast, especially if you go fast and go against the previous coiled up direction. Get a good bender. My cheap one on 90's looks funny, but still acceptable. Maybe it's the copper producer influencing the bend shape/tension. The bender is pretty nice in function, it's like all the other ratchet ones.

  • @stefanocubero6367
    @stefanocubero6367 25 днів тому

    Thanks man!

  • @pete8207
    @pete8207 25 днів тому

    Do these give you a superheat and subcool reading like the field piece does

  • @schlz69
    @schlz69 26 днів тому

    You missed Highside Chemicals "Just For Copper" its basically a copper glue. and has its place like each method you discussed, Just like Staybright 8 solder over brazing

  • @BetterMechanical
    @BetterMechanical 26 днів тому

    What are your thoughts on silver bearing solder/soldering? Just heard about it and am unsure

  • @l.crossjr
    @l.crossjr 27 днів тому

    Found one leaking through regardless off the adjustment position. Any tips before condemning?

  • @Samlol23_drrich
    @Samlol23_drrich 27 днів тому

    I use telta D

  • @user-li4ik9qs8c
    @user-li4ik9qs8c 28 днів тому

    Are they refillable?

  • @xyxl-gx6vn
    @xyxl-gx6vn 28 днів тому

    Would this just be called superheat? Genuinely asking.

    • @HVACKnowItAll
      @HVACKnowItAll 27 днів тому

      No, super heat is pipe temp minus SST

  • @johntaylor3043
    @johntaylor3043 28 днів тому

    To the point and informative, no fluff. Right on brother.

  • @rollaae82
    @rollaae82 29 днів тому

    What is the main reason for the acces port?

  • @NestorDelgado-fr6pu
    @NestorDelgado-fr6pu 29 днів тому

    Do you recommend always change your txv when changing a compresor.?

  • @Dicofole
    @Dicofole Місяць тому

    Can you make a video about Stay Brite 8 as an alternative to high temp brazing?

  • @bayouflats5054
    @bayouflats5054 Місяць тому

    🫤several residentials with o2? Not the way I shake and roll. 😆 And cramp! 🥴 But still really like the idea. I have bunch of 30 year old Goodman heat pumps for 3 rd floor Apts and no elevator. So, my old ass would benefit greatly with this. Appreciate maaaan. 🫵👍 I haven’t heard you going back because of a crappy joint, must be doing something right.

  • @bayouflats5054
    @bayouflats5054 Місяць тому

    Always appreciate, concise. 🫵👍

  • @hliz8818
    @hliz8818 Місяць тому

    Cool Video. Brazing with Nitrogen is cool.. i put regulator on 3.. at 6 I notice nitrogen pushing out filler... had that ever happened to you

    • @HVACKnowItAll
      @HVACKnowItAll Місяць тому

      If the flow is too high yes, that can happen

  • @realSamAndrew
    @realSamAndrew Місяць тому

    And you divide 35:in half and you get 17.5, which is close to your 20 degree split, which makes sense because that's halfway between the return air and the evaporator coils it passes through.

  • @ayoutubewatcher7009
    @ayoutubewatcher7009 Місяць тому

    Heat the pipe then the joint

    • @HVACKnowItAll
      @HVACKnowItAll Місяць тому

      Heat the joint them move the heat away not bring it towards

    • @eastcoast186
      @eastcoast186 Місяць тому

      Fantastic video and info thanks

    • @HVACKnowItAll
      @HVACKnowItAll Місяць тому

      My pleasure thank you! ​@@eastcoast186

  • @HVACKnowItAll
    @HVACKnowItAll Місяць тому

    Nitrogen brazing is a thing

  • @thesilentonevictor
    @thesilentonevictor Місяць тому

    Great video tech

  • @HVACKnowItAll
    @HVACKnowItAll Місяць тому

    The difference is important!